{"product_id":"mrcool-versapro-2nd-gen-18k-central-ducted-indoor-air-handler-mvp-18-hp-muah-230a00-o","title":"MRCOOL VersaPro 2nd Gen 18K BTU 1.5 Ton Central Ducted Air Handler — R-454B Indoor Unit Only","description":"\u003cp\u003eThe MRCOOL MVP-18-HP-MUAH-230A00-O is the indoor air handler for a compatible central ducted heat-pump system. In the 18,000 BTU\/h nominal equipment class (1.5 ton), it houses the indoor coil and blower that move conditioned air through your ductwork. It needs a verified matching outdoor unit and refrigerant connection to heat or cool; this listing is not a complete HVAC system.\u003c\/p\u003e\n\u003ch2\u003eWhat this indoor unit does\u003c\/h2\u003e\u003cp\u003eThe blower circulates air through the indoor coil and your supply ducts, while return ducts bring air back. Heating and cooling come from the complete matched heat-pump system. Choose the equipment using a load calculation and duct assessment rather than a square-footage shortcut.\u003c\/p\u003e\n\u003ch2\u003eFeatures that help with installation and service\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMulti-position cabinet for manufacturer-permitted installation configurations.\u003c\/li\u003e\n\u003cli\u003eSlide-out blower and a filter rack with a removable magnetic cover help with service access.\u003c\/li\u003e\n\u003cli\u003eSelf-diagnostic features support troubleshooting by following the model-specific manual.\u003c\/li\u003e\n\u003cli\u003eCompatible pre-charged Quick Connect and conventional installation paths are available for verified combinations; neither a line set nor a complete installation package is included here.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat you are buying\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eOne MVP-18-HP-MUAH-230A00-O indoor air handler and one MRCOOL touchscreen smart thermostat.\u003c\/strong\u003e An outdoor heat pump, refrigerant line set, optional electric heat kit, ductwork, supports, electrical materials and installation are separate requirements. The MRCOOL touchscreen smart thermostat is included at no additional charge. Additional adapters or accessories are not assumed included; verify the installation materials required for your selected configuration.\u003c\/p\u003e\n\u003ch2\u003eVerified outdoor equipment relationships\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaPro 2nd Gen:\u003c\/strong\u003e \u003ca href=\"https:\/\/mrcooldiydirect.com\/products\/mrcool-versapro-2nd-gen-18k-btu-1-5-ton-18-8-seer2-central-ducted-heat-pump-condenser?variant=49893237326141\"\u003eMVP-18-HP-C-230A00-O outdoor heat pump\u003c\/a\u003e (separate purchase).\u003c\/li\u003e\n\u003cli\u003eNo 18K HyperHeat central-ducted pairing is asserted. Shared-family compatibility does not mean every outdoor model is supported.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThese references identify manufacturer-documented pairings, not an approval to connect this unit to any same-capacity condenser. Do not substitute older R-410A equipment. Confirm the exact generation, model and configuration before replacing a component.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eManufacturer-supported information\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExact indoor model \/ SKU\u003c\/th\u003e\n\u003ctd\u003eMVP-18-HP-MUAH-230A00-O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment supplied\u003c\/th\u003e\n\u003ctd\u003eIndoor air handler only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal equipment class\u003c\/th\u003e\n\u003ctd\u003e18,000 BTU\/h \/ 1.5 ton; not a standalone system-output rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant compatibility\u003c\/th\u003e\n\u003ctd\u003eR-454B; use only the documented matched equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor power supply\u003c\/th\u003e\n\u003ctd\u003e115\/208-230 V, 60 Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor minimum circuit ampacity\u003c\/th\u003e\n\u003ctd\u003e5.5\/4.0 A, as listed by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIndoor maximum fuse \/ breaker\u003c\/th\u003e\n\u003ctd\u003e15 A; optional heater circuits are separately specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCabinet width × depth × height\u003c\/th\u003e\n\u003ctd\u003e17.52 × 21.02 × 45 in, upright reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet equipment weight\u003c\/th\u003e\n\u003ctd\u003e105.82 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer-listed airflow (Turbo \/ High \/ Medium \/ Low)\u003c\/th\u003e\n\u003ctd\u003e618.03 \/ 576.83 \/ 529.74 \/ 488.54 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFilter size\u003c\/th\u003e\n\u003ctd\u003e16x20x1 in; replaceable filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation orientation\u003c\/th\u003e\n\u003ctd\u003eMulti-position; follow exact upflow, downflow and horizontal drainage\/duct instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAuxiliary electric heat\u003c\/th\u003e\n\u003ctd\u003eOptional heat kit; not included. Verify model, electrical supply and installation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSystem efficiency\u003c\/th\u003e\n\u003ctd\u003eDepends on exact indoor\/outdoor pairing. No standalone SEER2, HSPF2 or incentive eligibility is claimed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePublished matched-system output examples\u003c\/h3\u003e\u003cp\u003eThe following manufacturer literature values apply to the exact outdoor pairing shown, not to this indoor unit by itself. Design conditions and the current matched-system documentation govern actual performance. The VersaPro brochure labels its specifications preliminary; no independent AHRI certification or tax-credit eligibility is promised here.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMatched outdoor model\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePublished cooling capacity\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePublished heating capacity\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eMVP-18-HP-C-230A00-O\u003c\/td\u003e\n\u003ctd\u003e18000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e18000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation and connection planning\u003c\/h2\u003e\u003cp\u003eFollow the exact installation manual for orientation, drain-pan and condensate routing, duct airflow, electrical supply, clearances and R-454B safety requirements. Refrigerant work and electrical work must meet applicable licensing, permit and code requirements. Use qualified assistance wherever required.\u003c\/p\u003e\u003cp\u003eManufacturer-approved NV Series R-454B pre-charged line sets can be used with verified configurations. Traditional non-pre-charged refrigerant piping requires the specified evacuation and charging procedure. Use the exact fittings\/adapters identified in the manual; an indoor connection size must not be assumed to equal the external line-set connection size. Permitted piping lengths, elevation and refrigerant requirements depend on the outdoor unit and complete arrangement. No line set or coupler is added automatically.\u003c\/p\u003e\n\u003ch2\u003eManufacturer limited warranty\u003c\/h2\u003e\u003cp\u003eThe applicable MRCOOL warranty provides 10-year limited parts coverage to the original owner, subject to its conditions and exclusions. This indoor unit does not contain the outdoor compressor; compressor coverage in the document applies to the corresponding compressor equipment. Coverage is non-transferable. It starts on the original installation date, or three months after the month of purchase if the installation date cannot be verified.\u003c\/p\u003e\u003cp\u003eThe warranty does not require a professional installer when the appropriate MRCOOL Quick Connect pre-charged line set is used; otherwise it requires one. Approved equipment matching, manufacturer instructions and applicable codes and licensing requirements still apply. No labor coverage is promised; refrigerant, freight, maintenance, diagnostics and other listed costs are excluded. Read the full applicable warranty before purchase.\u003c\/p\u003e\n\u003ch2\u003eManuals, specifications and support\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/doxrepo.mrcool.com\/mc-vp-HH-CDU-im-um-en-01.pdf\" rel=\"noopener\" target=\"_blank\"\u003eInstallation and operation manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/doxrepo.mrcool.com\/mc-vp-gen-2-br-en-01.pdf\" rel=\"noopener\" target=\"_blank\"\u003eVersaPro 2nd Gen specifications and literature\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/doxrepo.mrcool.com\/mc-vp-HH-CDU-2gen-ah-sm-en-01.pdf\" rel=\"noopener\" target=\"_blank\"\u003eIndoor air-handler service manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mrcool.com\/wp-content\/dox_repo\/mc-vp-CDU-wr-en-01.pdf\" rel=\"noopener\" target=\"_blank\"\u003eApplicable manufacturer limited warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/pages\/mrcool-product-documentation\"\u003eBrowse our existing Knowledge Center\u003c\/a\u003e · \u003ca href=\"\/pages\/manual-j-load-calculator\"\u003eHeating and cooling load calculator\u003c\/a\u003e · \u003ca href=\"\/pages\/contact\"\u003eAsk us to verify your exact equipment match\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eManufacturer images are shared MUAH-family photographs explicitly mapped to this model in the manufacturer resource file. Cabinet proportions and connections should be checked against the exact model drawing. The thermostat is included. Other illustrated equipment or accessories are not included merely because they appear in family literature.\u003c\/small\u003e\u003c\/p\u003e","brand":"MRCOOL","offers":[{"title":"Default Title","offer_id":67800827429181,"sku":"MVP-18-HP-MUAH-230A00-O","price":1396.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0779\/8069\/6893\/files\/mc-ahu-182430364860-ah-1000px-01.jpg?v=1792973267","url":"https:\/\/mrcooldiydirect.com\/products\/mrcool-versapro-2nd-gen-18k-central-ducted-indoor-air-handler-mvp-18-hp-muah-230a00-o","provider":"MRCOOL DIY Direct","version":"1.0","type":"link"}