MRCOOL Error Code Diagnostics Guide

MRCOOL Error Code Diagnostics Guide

MRCOOL Error Code Diagnostics Guide

Comprehensive troubleshooting and detailed solutions for every MRCOOL HVAC error code.

E0/EH00 – EEPROM Parameter Error

Meaning: The indoor unit has an EEPROM (Electrically Erasable Programmable Read-Only Memory) parameter error.

Detailed Solutions:

  • Power off the unit and restart it to reset the EEPROM parameters.
  • If the issue persists, consult the system manual to verify EEPROM settings.
  • Consider contacting an HVAC professional to reprogram or replace the EEPROM chip.
Pro Tip: Prevent EEPROM issues by ensuring your system is powered through a voltage stabilizer.
E1/EL01 – Communication Error

Meaning: There is a communication error between the indoor and outdoor unit.

Detailed Solutions:

  • For new installations: Shut down the unit immediately to prevent damage.
  • Verify wiring and ensure there is no damage or loose connections.
  • Check for potential interference from high-frequency electronics near the line set (e.g., computers, flat screens, microwaves).
  • For existing installations: This issue may indicate a board failure. Conduct AC and DC electrical tests to confirm the problem.
Pro Tip: Always separate HVAC wiring from high-frequency electronics to prevent interference-related errors.
E2/EH02 – Zero-Crossing Signal Error

Meaning: There is a zero-crossing signal detection error.

Detailed Solutions:

  • Check the power supply to ensure it is stable and within the recommended range.
  • Inspect the indoor unit's control board for potential faults.
  • Reset the system and monitor for recurring issues.
Pro Tip: Ensure proper grounding and stable voltage supply to avoid zero-crossing errors.
E3/E88/EH03 – Indoor Fan Speed Error

Meaning: The indoor fan speed has been out of control.

Detailed Solutions:

  • Ensure the fan motor is securely connected and operational.
  • Check for any obstructions or debris in the fan blades that might affect performance.
  • Inspect the control board for errors or loose connections.
  • Replace the fan motor if it is found to be faulty.
Pro Tip: Regularly clean and maintain fan blades to avoid speed issues and ensure proper airflow.
E4/EH60 – Indoor Room Temperature Sensor (T1) Error

Meaning: The indoor room temperature sensor (T1) is in open circuit or has short-circuited. The T1 sensor connected to the indoor board is loose or has gone out.

Detailed Solutions:

  • Inspect the T1 sensor for secure connections to the indoor board.
  • Replace the sensor if it shows signs of damage or malfunction.
  • Ensure the indoor board is functioning correctly to communicate with the sensor.
Pro Tip: Keep the area around the indoor unit clean to avoid dust accumulation on the T1 sensor.
E5/EH61 – Evaporator Coil Temperature Sensor (T2) Error

Meaning: The evaporator coil temperature sensor (T2) is in open circuit or has short-circuited. The T2 sensor connected to the indoor board is loose or has gone out.

Detailed Solutions:

  • Ensure the T2 sensor is securely connected to the indoor board.
  • Inspect the sensor for physical damage and replace if necessary.
  • Clean the evaporator coil to ensure no interference with sensor functionality.
Pro Tip: Conduct routine inspections of the evaporator coil and sensors during seasonal maintenance.
EC/EL0C – Refrigerant Leakage Detection

Meaning: The system has detected a potential refrigerant leak.

Detailed Solutions:

  • Perform a thorough soapy water test along the refrigerant lines to identify potential leaks.
  • Contact an HVAC professional to conduct a leak detection test if no visible leaks are found.
  • Repair any identified leaks and recharge the refrigerant to appropriate levels.
Pro Tip: Regularly inspect refrigerant lines for wear and tear to prevent leaks before they occur.
EH0b – Indoor PCB/Display Board Communication Error

Meaning: There is a communication error between the indoor PCB and display board.

Detailed Solutions:

  • Inspect the wiring connections between the PCB and display board to ensure they are secure.
  • Restart the system to reset communication protocols.
  • If the issue persists, consider replacing the indoor PCB or display board.
Pro Tip: Always power off the system before inspecting or replacing PCB components to avoid electrical damage.
F0 – Outdoor Unit Wiring/Voltage Error

Meaning: The outdoor unit has detected loose wiring, incorrect voltage, or a board issue.

Detailed Solutions:

  • Verify all wiring connections to the outdoor unit are secure and properly connected.
  • Measure the incoming voltage to ensure it matches the system's requirements.
  • Inspect the outdoor control board for signs of damage or malfunction and replace if necessary.
Pro Tip: Use a multimeter to check voltage levels and ensure stable power supply to avoid wiring issues.
F1/EC53 – Outdoor Ambient Temperature Sensor (T4) Error

Meaning: The outdoor ambient temperature sensor (T4) is in open circuit or has short-circuited.

Detailed Solutions:

  • Inspect the T4 sensor connection to the outdoor board for loose or disconnected wiring.
  • Replace the sensor if it shows signs of damage or malfunction.
  • Ensure proper placement of the sensor to accurately measure outdoor ambient temperature.
Pro Tip: During extreme weather conditions, ensure the sensor is not obstructed by debris or ice.
F2/EC52 – Condenser Coil Temperature Sensor (T3) Error

Meaning: The condenser coil temperature sensor (T3) is in open circuit or has short-circuited.

Detailed Solutions:

  • Verify the T3 sensor connection to the outdoor control board.
  • Inspect the condenser coil for any buildup of debris that may interfere with the sensor.
  • Replace the T3 sensor if it is damaged or malfunctioning.
Pro Tip: Regularly clean condenser coils to ensure proper operation of the temperature sensor.
F3/EC54 – Compressor Discharge Temperature Sensor (T5/TP) Error

Meaning: The compressor discharge temperature sensor (T5/TP) is in open circuit or has short-circuited.

Detailed Solutions:

  • Ensure the T5/TP sensor is securely connected to the outdoor board.
  • Inspect the sensor for physical damage or signs of malfunction and replace if needed.
  • Check for proper airflow around the compressor to avoid overheating issues.
Pro Tip: A clean and unobstructed outdoor unit ensures accurate temperature readings from the T5/TP sensor.
F4/EC51 – Outdoor Unit EEPROM Parameter Error

Meaning: The outdoor unit has encountered an EEPROM (Electrically Erasable Programmable Read-Only Memory) parameter error.

Detailed Solutions:

  • Reset the system by powering it off for a few minutes and then restarting.
  • Check the outdoor unit’s control board for faults and verify all connections.
  • Consult a qualified HVAC technician to reprogram or replace the EEPROM if the error persists.
Pro Tip: Regular power fluctuations can corrupt EEPROM data. Use a voltage stabilizer to protect your system.
F5/EC07 – Outdoor Fan Speed Error

Meaning: The outdoor fan speed is out of the acceptable range.

Detailed Solutions:

  • Inspect the outdoor fan motor and blades for obstructions, debris, or physical damage.
  • Check the fan speed sensor wiring for secure connections and proper functionality.
  • Replace the fan motor or speed sensor if any faults are detected.
Pro Tip: Keep the area around the outdoor unit clear of obstructions to ensure optimal fan performance.
F6/EC56 – Evaporator Coil Outlet Temperature Sensor (T2B) Error

Meaning: The evaporator coil outlet temperature sensor (T2B) is in open circuit or has short-circuited. This is commonly seen in multi-zone systems.

Detailed Solutions:

  • Inspect the T2B sensor cable for loose or disconnected wiring during shipping or due to vibration.
  • Shut down the unit and turn off the breaker before removing the panels.
  • Locate the white Molex plug, usually near the circuit board or terminal block, and ensure it is securely connected.
  • Reassemble the unit and restart to test functionality.
Pro Tip: Avoid rough handling during installation to prevent sensor disconnection in multi-zone units.
P0/PC00 – IPM Malfunction or IGBT Over-Current Protection

Meaning: Indicates a problem with the Intelligent Power Module (IPM) or excessive current in the IGBT.

Detailed Solutions:

  • Inspect the power supply for stability and ensure the voltage matches system requirements.
  • Check the outdoor unit control board for damage or loose connections.
  • Replace the IPM module if necessary and consult an HVAC professional for advanced diagnostics.
Pro Tip: Ensure all electrical connections are secure to prevent overcurrent issues in the IPM module.
P1/PC01 – Over Voltage or Under Voltage Protection

Meaning: The system has detected voltage levels outside the acceptable range.

Detailed Solutions:

  • Verify the incoming voltage using a multimeter to ensure it falls within the specified range.
  • Install a voltage stabilizer or surge protector if the power supply is unstable.
  • Inspect all electrical connections for secure and proper installation.
Pro Tip: Frequent voltage fluctuations can damage HVAC components. A stabilizer is a valuable investment for system longevity.
P2/PC02 – High Temperature Protection of IPM Module or High-Pressure Protection

Meaning: The system has detected high temperatures in the IPM module or excessive refrigerant pressure.

Detailed Solutions:

  • Ensure all line set connections are tightened properly with no threads showing.
  • Verify that service valves are fully open and locked in place.
  • Inspect the condenser for adequate ventilation and clear any obstructions around the outdoor unit.
Pro Tip: Overcharging refrigerant can lead to high pressure. Always verify refrigerant levels during servicing.
PC03 – Low Pressure Protection

Meaning: The system has detected low refrigerant pressure.

Detailed Solutions:

  • Inspect all line set connections, including air handlers, condensers, and extension couplers, to ensure they are fully tightened.
  • Verify that service valves are fully open and secured to the locking ring.
  • If the system is a multi-zone unit, check that the king valves on the vertical lines are fully open.
  • Check refrigerant pressure levels and recharge the system if necessary.
Pro Tip: Regularly inspect line set connections during routine maintenance to prevent pressure-related issues.
P3 – Low Ambient Temperature or Sensor Issue

Meaning: For Advantage systems, this error indicates that the outdoor ambient temperature is too low.

Detailed Solutions:

  • If outdoor temperatures are below -13°F, allow the system to defrost naturally.
  • Inspect the outdoor temperature sensor for damage or ice buildup.
  • Check for a dirty coil or low refrigerant charge and resolve as needed.
Pro Tip: Keep outdoor units clear of snow and ice during winter months to ensure proper functionality.
P4/PC04 – Inverter Compressor Drive Error

Meaning: This error is generally related to restrictions in the system or line set connections.

Detailed Solutions:

  • Ensure all line set connections are tightened properly, with no threads visible.
  • Verify that service valves are fully open and locked in place.
  • If the system is multi-zone, check that the king valves on vertical lines are fully open.
  • Inspect the inverter drive for signs of failure or overheating.
Pro Tip: Regular cleaning of the condenser and proper line set installation can prevent drive errors in multi-zone units.
PC08 – Current Overload Protection

Meaning: The system has detected an overload of current.

Detailed Solutions:

  • Inspect the power supply for stability and ensure it matches the system's voltage requirements.
  • Check all electrical connections for secure and proper installation.
  • Consult an HVAC technician to inspect and replace components, such as the compressor or control board, if necessary.
Pro Tip: Frequent current overloads can damage critical components. Use a surge protector for added safety.
P6/PC06 – Discharge Temperature Sensor Error

Meaning: The discharge temperature sensor is malfunctioning, usually indicating a refrigerant-related issue.

Detailed Solutions:

  • Inspect all line set connections and ensure they are fully tightened with no visible threads.
  • Check for leaks or oil residue on fittings, which could indicate a refrigerant issue.
  • If the system is a multi-zone unit, confirm that the king valves are open and properly seated.
  • Replace the discharge temperature sensor if it is damaged or malfunctioning.
Pro Tip: Keep refrigerant levels within manufacturer specifications to prevent sensor errors and maintain system efficiency.
P7 – USB Smart Controller Module Not Installed

Meaning: The USB Smart Controller module has not been detected.

Detailed Solutions:

  • Verify that the USB Smart Controller module is securely connected to the unit.
  • Inspect the USB port for any debris or physical damage that could interfere with connectivity.
  • Replace the USB Smart Controller module if it is not functioning correctly.
Pro Tip: Always handle USB connections with care to avoid damaging ports or modules during installation.
PCOL – Outdoor Temperature Too Low

Meaning: The outdoor temperature is too low, causing the condenser to shut off for safety reasons.

Detailed Solutions:

  • Allow the system to automatically resume operation when the temperature rises to an acceptable level.
  • If this error persists in warmer conditions, inspect the outdoor ambient temperature sensor for faults.
  • Ensure the system is installed in a location where it can operate within its specified temperature range.
Pro Tip: To prevent issues in cold climates, consider adding a low ambient temperature kit to support the system's operation.
-- (Double Dash) – Indoor Unit Modes Conflict

Meaning: The indoor unit modes are in conflict, with one unit attempting to heat while another is attempting to cool.

Detailed Solutions:

  • Switch all air handlers to the same mode (cooling, heating, or auto) to resolve the conflict.
  • Avoid using auto mode on multi-zone systems to prevent mode mismatches.
  • If the issue persists, reset the system by turning it off and on again.
Pro Tip: Set all zones to the same mode manually to avoid mode conflicts in multi-zone systems.
88+WiFi Symbol – Wiring Configuration Error

Meaning: This error indicates a bad wiring configuration at the unit.

Detailed Solutions:

  • Verify the wiring configuration matches the manufacturer's specifications, especially at the condenser and air handler.
  • Common mistakes include swapping wires 2 and 3; confirm their proper placement.
  • Inspect the wiring for damage or loose connections, and replace wires if necessary.
Pro Tip: When installing DIY systems, follow the red, white, and black/1-2-3 wiring sequence for accurate setup.
PC31 – Low Pressure Restriction or Sensor Disconnection

Meaning: The system has detected a low-pressure restriction or that the low-pressure sensor is disconnected.

Detailed Solutions:

  • Inspect all line set connections at the air handlers, condenser, and extension couplers to ensure they are fully tightened with no threads showing.
  • Verify that service valves are fully open and secured to the locking ring.
  • If the system is a multi-zone unit, ensure the king valves on the vertical lines are fully open.
  • Check the low-pressure sensor wiring for proper connection and replace if necessary.
Pro Tip: Regularly inspect system connections and sensors during maintenance to prevent low-pressure issues.
CF – Temperature Adjustment Required

Meaning: Indicates that a minor adjustment in the set temperature is required.

Detailed Solutions:

  • Raise or lower the set temperature by a few degrees and monitor the system's response.
  • Ensure the thermostat is functioning correctly and not obstructed by external factors, such as direct sunlight or drafts.
Pro Tip: Keep the thermostat in a central location and away from heat sources for accurate temperature readings.
DF – Defrost Mode

Meaning: The unit is currently running in defrost mode at the condenser to remove ice buildup.

Detailed Solutions:

  • Allow the unit to complete the defrost cycle; it will resume normal operation automatically.
  • If the defrost mode activates frequently, inspect the outdoor coil for cleanliness and airflow obstructions.
  • Verify that the defrost sensor is functioning correctly and replace it if necessary.
Pro Tip: During cold weather, ensure the area around the outdoor unit is clear of snow and debris to optimize defrost cycles.
FP – Freeze Protection Mode

Meaning: The unit is currently running in freeze protection mode to prevent freezing in the system.

Detailed Solutions:

  • Allow the system to continue running in freeze protection mode; this is a normal operating feature under specific conditions.
  • Ensure the area around the outdoor unit is free from obstructions and debris to optimize airflow.
  • If the freeze protection mode engages frequently, inspect the refrigerant levels and system settings to ensure proper operation.
Pro Tip: Regularly clean and maintain the outdoor unit to prevent conditions that could trigger freeze protection mode unnecessarily.
FC – Forced Cooling Mode

Meaning: The unit is currently running in forced cooling mode, often used during specific maintenance or diagnostic procedures.

Detailed Solutions:

  • Allow the system to complete its forced cooling cycle if it was intentionally initiated.
  • Check system settings to ensure forced cooling was not accidentally activated.
  • If the system remains stuck in forced cooling mode, reset the unit by turning off the power and restarting.
Pro Tip: Forced cooling mode is typically used during maintenance. Refer to the system manual to understand when and how to utilize this feature effectively.