MRCOOL® Authorized Dealer
Authorized Dealer
Genuine OEM Replacement Parts

MRCOOL 15 kW Heat Kit for ProDirect Series (PHK15H)

Brand MRCOOL
MRCOOL® PART NUMBER PHK15H
Regular price $409.00
Sale price $409.00 Regular price $511.25
You Save: $102.25
SALE Sold out
!
Compatibility matters. Replacement parts are model-specific. Images may be stock photos, and small visual differences may exist between production batches. Verify your model number, serial number, and existing part before placing an order.
Currently Out of Stock
This replacement part is currently unavailable. Contact us for availability or compatibility help.

Not Sure This Is The Correct Part?

Send us your indoor unit model number, serial number, and photos of the existing part before ordering. This helps us verify compatibility and reduce the chance of ordering the wrong replacement part.

MRCOOL 15kw Heat Kit for ProDirect  Series (PHK15H)

 

Final Sale: MRCOOL Accessories are non-returnable. 

Contact a representative if you need assistance with finding the right HVAC Accessory.

 Dimensions 

2.6" D x 12" H x 19" W

Voltage

240 V

Max Fuse Breaker

60&60 A

Min Circuit Ampacity

40 A

Rated Load

15

Auxiliary Heater Sizes

15 KW

UL Listed

yes

 

Install Manual

 

 

 

    Confirmed Fitment

    No confirmed fitment models have been added yet. Verify compatibility before ordering.

    Part Details

    BrandMRCOOL
    MRCOOL® Part NumberPHK15H

    Common Symptoms

    No common symptom information has been added for this part type yet.

    Installation Notes

    This replacement part should be installed by a qualified technician or a capable installer familiar with mini split service procedures. Always disconnect power before servicing HVAC equipment.

    No Q&A content has been added for this replacement part yet.

    HEAT STRIP SIZING & PERFORMANCE

    What Affects Emergency Heat & Heat Strip Requirements?

    The correct electric heat strip size depends on more than air handler tonnage. Climate, home insulation, electrical capacity, system design, and heating demands all affect which heat kit is appropriate for your HVAC system.

    🌡️

    Cold Climate Performance

    Homes in colder climates often require larger auxiliary heat capacity because heat pumps lose efficiency as outdoor temperatures fall

    Tip

    Northern climates may benefit from larger backup heat kits than mild-weather regions.

    Available Electrical Service

    Heat strips draw significant electrical current. Your panel capacity, breaker size, and wiring must support the selected heat kit.

    Tip

    Always verify electrical requirements before upgrading to a larger kW heat strip.

    🏠

    Insulation Quality

    Poor insulation increases heat loss and can increase demand on both the heat pump and electric backup heat system.

    Tip

    Improving insulation may reduce heating costs more than increasing heat strip size.

    📏

    Home Size

    Larger homes generally require more heating capacity, but square footage alone should not determine heat strip selection.

    Tip

    Heat load calculations are more accurate than simple square-foot estimates.

    🌬️

    Air Leakage & Drafts

    Drafty homes, large entryways, and poorly sealed structures can dramatically increase heating demand.

    Tip

    Air sealing improvements can significantly improve HVAC performance.

    🔧

    Air Handler Compatibility

    Heat strips are not universal. Each air handler has specific approved heat kit sizes and electrical configurations.

    Tip

    Always verify your air handler model number before ordering a heat strip.

    Heat strips provide auxiliary and emergency heat when additional heating capacity is needed. Choosing the correct heat kit requires verifying air handler compatibility, electrical requirements, climate conditions, and manufacturer specifications.

    AUXILIARY & EMERGENCY HEAT FAQHEAT KIT BUYING GUIDE

    Frequently Asked Questions About Electric Heat Strips, Auxiliary Heat & Emergency Heat Kits

    Expert answers about HVAC heat strips, backup electric heat, air handler compatibility, heat kit sizing, installation, and cold-weather heating performance.

    How Do HVAC Heat Strips Work?

    HVAC heat strips are electric resistance heating elements installed inside compatible air handlers. When outdoor temperatures become too cold for the heat pump to efficiently provide heat, the heat strips activate to supplement heating output. They can also operate as emergency heat if the outdoor heat pump unit is unavailable or being serviced.

    What Is Emergency Heat?

    Emergency heat is a thermostat setting that bypasses the outdoor heat pump and uses only the electric heat strips inside the air handler. This mode is typically used during equipment failures, extreme weather conditions, or while servicing the outdoor unit.

    What Is The Difference Between Auxiliary Heat And Emergency Heat?

    Auxiliary heat automatically activates when the heat pump requires additional heating capacity to maintain indoor temperature. Emergency heat is manually selected and relies solely on the electric heat strips, disabling the outdoor heat pump.

    How Do I Know If This Heat Strip Fits My Air Handler?

    Heat strips are not universal. Compatibility depends on the manufacturer, air handler model, electrical configuration, and approved heat kit size. Always verify your air handler model number before ordering. The fitment information on this page identifies compatible systems and air handler series.

    What Size Heat Strip Do I Need?

    Heat strip sizes commonly range from 5 kW to 20 kW depending on the HVAC system and home heating requirements. The correct size depends on:

    • Air handler compatibility
    • Electrical service capacity
    • Climate zone
    • Home size
    • Heat pump capacity

    Always follow the manufacturer's approved heat kit specifications.

    Can I Install A Heat Strip Myself?

    Heat strip installation requires access to high-voltage electrical components inside the air handler. Installation should be performed by a qualified HVAC technician or licensed electrician familiar with local electrical codes and HVAC equipment requirements

    Do Heat Strips Increase Electric Bills?

    Heat strips consume more electricity than a heat pump operating normally. However, they provide reliable supplemental heating during cold weather and help maintain indoor comfort when outdoor temperatures reduce heat pump efficiency.

    Can A Heat Pump Operate Without A Heat Strip?

    In many regions, yes. However, homes located in colder climates often benefit from auxiliary heat strips because they provide supplemental heating during defrost cycles and extremely cold outdoor temperatures.

    Why Is My HVAC System Showing Auxiliary Heat?

    Auxiliary heat commonly activates when:

    • Outdoor temperatures are very low
    • The thermostat is raised several degrees at once
    • The system is in a defrost cycle
    • Additional heating capacity is needed

    This is generally normal operation for a heat pump system equipped with electric heat strips.

    How Long Do HVAC Heat Strips Last?

    Heat strips can often last 10 to 20 years when properly installed and operated. Factors such as electrical issues, airflow restrictions, and excessive cycling can reduce service life.

    What Are Common Signs Of A Failed Heat Strip?

    Common symptoms include:

    • Cold air during heating operation
    • Auxiliary heat not functioning
    • Tripped breakers
    • Burnt electrical odor
    • Insufficient heating capacity
    • Error codes related to electric heat operation

    Diagnosis should be performed by a qualified technician.

    Why Buy Genuine OEM Heat Strips?

    OEM heat strips are engineered specifically for compatible air handlers and are tested to meet manufacturer performance and safety requirements. Using the correct OEM heat kit helps ensure proper operation, electrical compatibility, and warranty compliance.